Dewpoint
Temperature at given saturation pressure of water vapour

TD = dewpoint [K]
(after B. Hardy, Proc. Int. Symp. Humidity & Moisture, Teddington, London, 1998)

TD = {2.0798233·102 - 2.0156028·101 ln e + 4.6778925·10-1 (ln e)2 -9.2288067·10-6 (ln e)3 } /
        {1 - 1.3319669·10-1 ln e + 5.6577518·10-2 (ln e)2 - 7.5172865·10-5 (ln e)3 }

valid in range -100 °C < T < 100 °C

e = saturation vapour pressure [Pa]

TD (°C)
  e (hPa)

e from hPa to hPa

Dewpoint calculation e: Pa     

TD: K

Dewpoint